View Larger Image
|
|
DTBB - DTBX Digital tension meter for measuring all kinds tapes and bands | Tension meter for measuring all kinds of tapes and bands, such as textile ribbons, films, foils, fiber bunches, etc.
The model DTBB is recommended where the DTMB cannot be used. The DTBX is can be used in places where the DTMX cannot be used.
Note: This model does not include a material thickness compensator
|


| Model |
Ranges | Measuring Head Width** mm | Roller Widths mm |
| DTBB-200 |
2.0-200.0 | 55 | 7,10,15,20 |
| DTBB-500 |
5.0-500.0 | 55 | 7,10,15,20 |
| DTBB-1000 |
50-1000 | 55 | 7,10,15,20 |
| DTBB-2000 |
200-2000 | 55 | 7,10,15,20 |
| DTBB-2500 |
250-2500 | 117 | 7,10,15,20 |
| DTBB-5000 |
500-5000 | 117 | 7,10,15,20 |
| DTBB-10K |
1.00-10.00 daN | 117 | 7,10,15,20 |
| DTBB-20K-L |
2.00-20.00 daN | 217 | 7,10,15 |
| DTBB-50K-L |
5.00-50.00 daN | 217 | 7,10 |
| DTBX-200 |
2.0-200.0 | 55 | 7,10,15,20 |
| DTBX-500 |
5.0-500.0 | 55 | 7,10,15,20 |
| DTBX-1000 |
50-1000 | 55 | 7,10,15,20 |
| DTBX-2000 |
200-2000 | 55 | 7,10,15,20 |
| DTBX-2500 |
250-2500 | 117 | 7,10,15,20 |
| DTBX-5000 |
500-5000 | 117 | 7,10,15,20 |
| DTBX-10K |
1.00-10.00 daN | 117 | 7,10,15,20 |
| DTBX-20K-L |
2.00-20.00 daN | 217 | 7,10,15 |
| DTBX-50K-L |
5.00-50.00 daN | 217 | 7,10 | | |
Other measuring head widths available on request.
Other units of measure available, such as g or kg.
** Outer distance between outside guide rollers
Special calibration using customer supplied samples is recommended, if process material differs significantly from the SCHMIDT calibration material in diameter, rigidity or shape. For this purpose a material sample of about 5 m should be supplied. |
|   |

 Delivery includes:
Tension meter with carrying case and batteries, operating instructions in English or German as requested |  |
Tension View Data Transfer & Analysis Program for DTMX Tension Meter |  |
Displays, Records, Graphs & Prints data from DTMX Tension Meter
Real-Time data-logging
| | | Click image for more info
|


| Calibration: |
According to SCHMIDT factory procedure |
| Accuracy: |
for 10% to 90% of range: ± 0.5% full scale and ± 1 digit remaining range and other calibration material: ± 3% full scale and ± 1 digit |
| Overrange: |
Approx. 15% full scale, without accuracy guarantee |
| Overload protection: |
100% of tension range |
| Measuring principle: |
Strain gauge bridge |
| Measuring roller deflection: |
0.2 mm max. |
| Signal processing: |
Digital |
| Measuring frequency: |
62 measurements/sec |
| Converter: |
12 bit A/D |
| Temperature coefficient: |
Gain: less than ± 0.01% full scale/°C Zero point: less than ± 0.3% full scale/°C |
| Display: |
4-digit LCD, 12 mm high |
| Display update rate: |
0.5,1,2 or 4 seconds selectable |
| Memory: |
Last, MIN, MAX, PEAK values |
| Field adjustment: |
± 7 steps in 1.5% increments |
| Temperature range: |
10 - 45ºC |
| Air humidity: |
85% RH, max. |
| Power supply: |
4 size AA batteries 1.5 V (about 20 hours of continuous use) |
| Auto power off: |
After 2 minutes of non-use |
| Housing material: |
Die-cast aluminium |
| Housing dimensions: |
235 x 76 x 45 mm (L x W x H) |
| Weight, net (gross): |
up to Model -10K approx. 680 g (1500 g) Model -20K-L and higher approx. 1000 g (2200 g) |
|
Specifications for Model DTBX, same as Model DTBB plus:
|
| Extended memory: |
up to 100 tension values, average, standard deviation |
| Digital output: |
RS232C (4800, 8, N, 2) |
| Analog output: |
0-1 V DC (conversion rate 16 ms) |
| Digimatic: |
Mitutoyo |
|
|