View Larger Image
|
|
DTMX For applications requiring additional process data | 9 ranges, 0.1 - 200.0 g to 5 - 50 kg
The new CHECK-LINE DTMX Digital Tension Meters accurately measure the running line tensions of yarns, fibers, wires, cables, optic fibers and similar process materials.
It's unique design combines the latest microprocessor technology with the reliability, simplicity and ruggedness found in CHECK-LINE mechanical tension meters.
The DTMX provides the critical process information required to meet today's strict quality reporting systems mandated under ISO 9000 guidelines. |

 2 Memory modes for 100 data values and statistics:
- Continuous storage
- On-demand storage | Analog and serial interfaces | Calibration to customer supplied material is available (up to four different material calibrations) | Precision V-grooved rollers for line speeds up to 5,000 m/min | Memory for up to 100 tension values plus MIN, MAX, PEAK values
- automatic calculation of average and standard deviation
-all these data values can be recalled in the display or downloaded to a printer or Personal Computer. | Material selector switch for textile and wire applications (Tex and Wire) assures highest accuracy |
| Selectable update rates
(0.5, 1, 2, or 4 seconds) to
provide steady readings
when tensions fluctuate
(electronic damping) | Built-in mounting holes
permit fixed installation
for online use | Can be connected to a PC or printer for data output | Thickness Compensator Automatically Adjusts Calibration | DIP switch for adjustment by operator, e.g. display update rate |
|
Built-in Datalogger
The DTMX built-in datalogger stores up to 100 tension values and automatically calculates maximum, minimum, peak, average and standard deviation values. The data values and summary statistics can be recalled to the display for viewing or downloaded to a printer or Personal Computer.
The datalogger can be set to store in two different modes. In the On-Demand Mode, a tension value is stored, each time the STORE key is pressed. In the Continuous Mode, the STORE key is pressedto start continuous datalogging. Each displayed value will be stored until the memory is filled or until the STORE key is pressed again to stop the datalogging. The stored data is retained in memory for the life of the batteries.
|


Tension View Data Transfer & Analysis Program for DTMX Tension Meter |  |
Displays, Records, Graphs & Prints data from DTMX Tension Meter
Real-Time data-logging
| | | Click image for more info
|
CS-DTMX Serial Cable for DTMX |  |
Connects DTMX Tension Meter to a PC or printer
| | | Click image for more info
|
P-DTMX Portable Printer for DTMX |  |
Small, portable and easy to use
Prints statistical data from the DTMX Digital Tension Meter
| | | Click image for more info
|
Roller Guide Rollers for hand-held tension meters |  |
| | | Click image for more info
|


| Model |
Ranges | Head width * (mm) | MTC*** | Resolution |
| DTMX-200 |
0.1 - 200.0 | 65 | | 0.1 cN |
| DTMX-500 |
0.1 - 500.0 | 65 | XXX | 0.1 cN |
| DTMX-1000 |
50 - 1000 | 65 | XXX | 1 cN |
| DTMX-2000 |
200 - 2000 | 65 | XXX | 1 cN |
| DTMX-2500 |
250 - 2500 | 116 | XXX | 1 cN |
| DTMX-5000 |
500 - 5000 | 116 | XXX | 1 cN |
| DTMX-10K |
1.00 -10.00 daN | 116 | XXX | 0.01 daN |
| DTMX-20K-L |
2.00 -20.00 daN | 216 | XXX | 0.01 daN |
| DTMX-50K-L |
5.00 -50.00 daN | 216 | | 0.01 daN | | |
Other measuring head widths available on request.
Other units of measure are available, such as g or kg and oz or lb.
* Depending on model, either width of filament guide or outer distance between outside guide rollers
***MTC = Material Thickness Compensator
|
|   |

  |

| Model
|
Factory
Calibration
Material
PA*** |
Factory
Calibration Material
Cu-wire annealed****
|
Material
thickness
compensator |
| DTMX-200 |
0.12 mm Ø |
0.10mm Ø |
|
| DTMX-500 |
0.12 + 0.20 mm Ø |
0.16 + 0.25 mm Ø |
Built-In |
| DTMX-1K |
0.20 + 0.40 mm Ø |
0.25 + 0.40 mm Ø |
Built-In |
| DTMX-2K |
0.40 + 0.70 mm Ø |
0.40 + 0.60 mm Ø |
Built-In |
| DTMX-2.5KB |
0.40 + 0.70 mm Ø |
0.40 + 0.60 mm Ø |
Built-In |
| DTMX-5KB |
0.60 + 1.20 mm Ø |
0.60 + 1.00 mm Ø |
Built-In |
| DTMX-10KB |
0.80 + 1.40 mm Ø |
0.70 + 1.20 mm Ø |
Built-In |
| DTMXL-20KB |
1.20 + 1.80 mm Ø |
steel rope 1.5 und 2.0 mm Ø |
|
| DTMXL-50KB |
steel rope 1.5 mm Ø 7x7x0.2) |
steel rope 2.0 mm Ø (7x7x0.25) |
|
*** Suitable for 95 % of applications
**** Accuracy: ± 3 % full scale (FS) and ± 1 dgit |
Calibration to customized material:
If process material differs significantly from the factory calibration material in diameter, rigidity or shape, special calibration using customer supplied samples is recommended. For this purpose a material sample of about 5 m should be supplied. |
|

 Delivery includes:
Tension meter with carrying case and batteries, operating instructions in English or German as requested |  |


| * Accuracy: |
± 0.5% Full Scale, ± 1 digit (10 - 90% of Full Scale) ± 3.0% Full Scale, ± 1 digit (Remaining portion of range) |
| Measuring Frequency: |
62 measurements/second |
| Deflection of Sensing Roller |
0.2 mm (maximum) |
| Overload Capacity: |
200% of Full Scale |
| Display: |
4-Digit LCD, 12 mm high |
| Display Update Rate: |
0.5, 1.0, 2.0 or 4.0 seconds, dip-switch selectable |
| Standard Memory: |
Last, maximum, minimum and peak |
| Field Calibration Adjustment: |
± 7 steps, 1.5% per step |
| Battery Type: |
Four (4) 1.5 V AA (included) |
| Battery Life: |
20 hours, continuous use |
| Auto Power Off: |
After 2 minutes of non-use |
| Roller Material: |
Hard Coated (Standard) Hardened Steel (ST) (optional) Ceramic (CE) (optional) Plastic (PL) (optional) |
| Maximum Speed |
2000 m/min (standard) 2500 m/min (U) |
| Housing Material: |
Die-cast Aluminum |
| Weight: |
1.43 lbs. (650 g) |
| Temperature coefficient: |
32 to 132 °F (0 to 45 °C) |
| Warranty: |
1 year |
| Memory Capacity: |
100 values plus maximum, minimum, average, peak, standard deviation and memory location |
| Memory Operation: |
Continuous Mode: Automatic storage of each displayed value until memory is full |
| Serial Output: |
RS-232C (4800 baud, 8 bit word length, no parity, 2 stop bits) |
| Analog Output: |
0-1 VDC, proportional to tension range |
| AC Adapter (optional): |
6 VDC @ 300 mA, for continuos in-line use |
| Note |
* Quoted accuracy can only be gauranteed on standard factory calibration materials. Because of the wide variety of customer samples, accuracy may exceed standard tolerances. |
|
|