View Larger Image
|
|
DTVB - DTVX Digital tension meter with measuring head rotated by 90° | Tension meter with small rotated measuring head, where access space is limited or where filaments run close together.
The model DTVB is recommended where the standard model DTMB cannot be used. The model DTVX is a special purpose model for when the standard model DTMX cannot be used.
Note: This model does not include a material thickness compensator
|

 Turned-up outer finger edges guide the running filament into the roller grooves | Small, ball-bearing mounted, V-grooved guide rollers
| Filament guide and roller shifting mechanism ensure easy acquisition of the running material | Rugged aluminium housing | Specific Test Report with calibration report optionally available
|
| Length of measuring head approx. 59 mm | Everything in operator's view:
- the guide rollers
- the measured material
- the readings | Ball-bearing mounted, V-grooved guide rollers | Battery operated (AC adapter for continuous operation available) |
|


| Model |
Ranges | SCHMIDT Calibration Material* |
| DTVB-200 |
2.0-200.0 | PA: 0.12 mm Ø |
| DTVB-500 |
5.0-500.0 | PA: 0.20 mm Ø |
| DTVB-1000 |
50-1000 | PA: 0.30 mm Ø |
| DTVB-2000 |
200-2000 | PA: 0.50 mm Ø |
| DTVX-200 |
2.0-200.0 | PA: 0.12 mm Ø |
| DTVX-500 |
5.0-500.0 | PA: 0.20 mm Ø |
| DTVX-1000 |
50-1000 | PA: 0.30 mm Ø |
| DTVX-2000 |
200-2000 | PA: 0.50 mm Ø | | |
Other units of measure available, such as g.
Measuring Head Width 40 mm (Outer distance between outside guide rollers)
Measuring Head Length 59 mm
* Suitable for 95% of applications - PA = Polyamide Monofilament
Special calibration using customer supplied samples is recommended, if process material differs significantly from the SCHMIDT calibration material in diameter, rigidity or shape. For this purpose a material sample of about 5 m should be supplied.
|
|   |

 Delivery includes:
Tension meter with carrying case and batteries, operating instructions in English or German as requested |  |


| Calibration: |
According to SCHMIDT factory procedure |
| Accuracy: |
for 10% to 90% of range: ± 0.5% full scale and ± 1 digit remaining range and other calibration material: ± 3% full scale and ± 1 digit |
| Overrange: |
Approx. 15% full scale, without accuracy guarantee |
| Overload protection: |
100% of tension range |
| Measuring principle: |
Strain gauge bridge |
| Measuring roller deflection: |
0.2 mm max. |
| Signal processing: |
Digital |
| Measuring frequency: |
62 measurements/sec |
| Converter: |
12 bit A/D |
| Temperature coefficient: |
Gain: less than ± 0.01% full scale/°C Zero point: less than ± 0.3% full scale/°C |
| Display: |
4-digit LCD, 12 mm high |
| Display update rate: |
0.5,1,2 or 4 seconds selectable |
| Memory: |
Last, MIN, MAX, PEAK values |
| Field adjustment: |
± 7 steps in 1.5% increments |
| Temperature range: |
10 - 45ºC |
| Air humidity: |
85% RH, max. |
| Power supply: |
4 size AA batteries 1.5 V (about 20 hours of continuous use) |
| Auto power off: |
After 2 minutes of non-use |
| Housing material: |
Die-cast aluminium |
| Housing dimensions: |
235 x 76 x 45 mm (L x W x H) |
| Weight, net (gross): |
approx. 680 g (1500 g) |
|
Specifications for Model DTVX, same as Model DTVB plus:
|
| Extended memory: |
up to 100 tension values, average, standard deviation |
| Digital output: |
RS232C (4800, 8, N, 2) |
| Analog output: |
0-1 V DC (conversion rate 16 ms) |
| Digimatic: |
Mitutoyo |
|
|