| Display: |
LCD-display with 2 rows of digits Yellow background illumination 6-digit displ. of real value, 7 mm high 6-digit displ. of set value, 4 mm high Decimal point can be programmed Suppression of leading zero Measurement units can be progr. in “m”, “dm”, “cm”, “mm”, “l” |
| Operation, keypad: |
Front membr. w. short-stroke keys |
| Front dimensions: |
DIN housing 48 x 48 mm |
| Mounting: |
Front installation |
| Fastening: |
Clamping frame |
| Weight: |
Version AC: ca. 260 g Version DC: ca. 140 g |
| Type of connection: |
Plug-in screw terminals Grid 5.08 mm / 3.81 mm |
| Core cross-section: |
Max. 1.5 mm2 |
| Housing material: |
Polycarbonate black, UL 94V-0 |
| Membrane material: |
Polyester |
| Supply voltage: |
Choice of two voltages (AC) via switch on device. When supplied, always higher voltage adjusted. 115 / 230 VAC ±10 % (50 / 60 Hz) 24 / 48 VAC ±10 % (50 / 60 Hz) 12...30 VDC ±10 %, 5 % residual ripple |
| Power consumption: |
5 VA, 4 W |
| Sensor supply: |
12...26 VDC / 60 mA |
| Signal inputs: |
Comparator inputs PNP, NPN or AC-logic, NAMUR Voltage level 4...40 V Input resistance 3 kOhm |
| Counting rate: |
Main counter: 3 Hz, 25 Hz, 10 kHz Batch counter: Max. 20 Hz |
| Control inputs: |
3 control inputs for reset, stop, hold, print, keylock etc. |
| Signal outputs: |
Can be programmed as momentary or permanent signals Impulse time can be programmed 0.01...99.99 s |
| Relay signal outputs: |
2 floating relays to be programmed as normally open or normally closed contact Internal spark suppression Max. switch. volt. 250 VAC/110 VDC Max. switch. power 1 A Max. switch. capacity 150 VA /30 W |
| Electronic outputs: |
Optocoupler Max. switching voltage 50 V Max. switching power 25 mA |
| Data storage: |
> 10 years via EEPROM |
| Operation modes: |
To be programmed as adding or subtracting |
| Counting mode of signal inputs A / B: |
UP / DOWN, A - B, A + B, A 90° B x1, A 90° B x2, A 90° B x4 |
| Ambient temperatue: |
0...+50 °C |
| Storage temperature: |
-20...+70 °C |
| Relative humidity: |
Max. relative humidity 80 %, at 25 °C, non-condensing |
| Protection: |
Front IP 65 to DIN 40050 |
| General rating: |
EN 61010 Part 1 - Protection class II - Overvoltage protection categ. II - Contamination factor 2 |
| Interference immunity: |
EN 50082-2 |
| Emitted interference: |
EN 50081-1 |