| Gauge version: |
DCF-3000PRO-F10: for measurements on iron/steel up to 10mm |
| Gauge type: |
Gauge with separate probe (1 m of fixed cable) |
| Measuring principle: |
Magnetic induction method |
| Measuring range: |
0 ... 10 mm / 0 ... 0.4” (selectable units µm/mils) |
| Tolerance: |
± (5 µm/0.2 mils + 1% of reading) |
| Resolution: |
1 µm/0.04 mils or < 0.2 % of reading |
| Display: |
4-digit display (digit height 10 mm/0.4”) and 32 alphanumerical characters; switchable backlight |
| Minimum measurement area: |
20 mm x 20mm/0.8“ x 0.8“ |
| Minimum curvature radius: |
convex 5mm/0.2”; concave 16mm/0.6” |
| Minimum substrate thickness: |
0.5mm/20 mils |
| Calibration methods: |
- Factory calibration: no calibration required for standard applications - Zeroing (1-point calibration): measurements on small geometries - Zeroing and foil calibration (2-point calibration): increased measuring accuracy - Two-foil calibration: especially for rough, sand-blasted surfaces - CTC: calibration on coated object if zeroing is not possible - Zero offset: addition/subtraction of a constant value to/from the reading |
| Limit values: |
Selectable; optical and acoustic signal if limit value is exceeded |
| Scan mode: |
For continuous measurements; for the quick recognition of coating thickness variations; with permanent display of minimum and maximum reading |
| Statistics: |
Single-value statistics: n, avarage x, s, kvar, min, max, cp, cpk from max. 10,000 readings Block-value statistics: n, avarage x , avarage s, avarage kvar , min, max, cp, cpk; block size 3 to 100 readings |
| Data memory: |
10,000 readings in max. 500 selectable files; alphanumerical file names; stored readings and statistical values individually recallable |
| Interfaces: |
Infrared and serial RS232 interface |
| Language: |
Operator prompting and documentation in German, English, French (optional other languages) |
| Operating temperature: |
0 °C to 50 °C/32 °F to 122 °F (storage temperature - 20 °C to +60 °C/-4 °F to 140 °F) |
| Surface temperature: |
-15 °C to 60 °C/5 °F to 140 °F (briefly above 60 °C/140 °F up to 150 °C/302 °F) |
| Power supply: |
2 x round cell (AA) 1.5 V up to 60 hours of operating time |
| Housing/keypad: |
Protection class IP52 (protection against dust and dripping water) |
| Dimensions: |
Gauge: 140 mm x 62 mm x 30mm/5.6” x 2.5” x 1.2” (HxWxD) Probe F10: dia. 25 mm x 45 mm/dia. 1” x 1.8” |
| Weight: |
approx. 200 g/7 oz (gauge including batteries and probe) |
| Standards: |
DIN EN ISO, ASTM, BS |
| Warranty: |
1 year |